clear;
sessions 10;
tenacity 4;
sleep 20;
DATEFORM ANSIDATE;\
show version;
.LOGON 127.0.0.1/TDUSER, TDUSER
DROP TABLE tduser.M1;
DROP TABLE TDUSER.ERR1;
DROP TABLE TDUSER.ERR2;
CREATE SET TABLE tduser.M1
(
MANUFACTURER_ID INTEGER,
MANUFACTURER_NAME VARCHAR(10),
MANFACTURE_CODE VARCHAR(3)
)
UNIQUE PRIMARY INDEX ( MANUFACTURER_ID );
SET RECORD VARTEXT "|";
DEFINE
delim0 (varchar(1)),
MANUFACTURER_ID (varchar(2)),
delim1 (varchar(1)),
MANUFACTURER_NAME (varchar(10)),
delim2 (varchar(1)),
MANFACTURE_CODE (varchar(3)),
delim3 (varchar(1)),
newlinechar (varchar(1))
FILE = C:\Documents and Settings\code.txt;
SHOW;
BEGIN LOADING TDUSER.M1 ERRORFILES TDUSER.ERR1, TDUSER.ERR2;
.CHECKPOINT 1000;
.INDICATORS;
INSERT INTO TDUSER.M1 VALUES (:MANUFACTURER_ID,:MANUFACTURER_NAME,:MANFACTURE_CODE) ;
END LOADING;
logoff;
LOG+++++++++++++++++++++++++++
===================================================================
= =
= FASTLOAD UTILITY VERSION 13.00.00.004 =
= PLATFORM WIN32 =
= =
===================================================================
===================================================================
= =
= Copyright 1984-2009, Teradata Corporation. =
= ALL RIGHTS RESERVED. =
= =
===================================================================
**** 00:51:07 Processing starting at: Sun Jun 16 00:51:07 2013
0001 clear;
**** 00:51:07 Warning: All previous column and file definitions cleared
0002 sessions 10;
**** 00:51:07 FDL4866 SESSIONS command accepted
0003 tenacity 4;
**** 00:51:07 Tenacity Enabled: 4 hour(s)
0004 sleep 20;
**** 00:51:07 Sleep Minutes Set: 20 minute(s)
0005 DATEFORM ANSIDATE;\
**** 00:51:07 Date/Time Format set to ANSIDATE
**** 00:51:07 Command completed successfully
0006 show version;
FastLoad Version 13.00.00.004 for Win 32 running Windows Sockets
FastLoad : 13.00.00.08
FastCmds : 13.00.00.11
FastIO : 13.00.00.02
FastMBCS : 13.00.00.02
FastNtfy : 13.00.00.00
FastPars : 13.00.00.06
FastSQL : 13.00.00.16
FastUtil : 13.00.00.04
Standalone Data Connector : 13.00.00.001
PMPROCS : 13.00.00.01
PMRWFMT : 13.00.00.03
PMTRCE : 13.00.00.01
PMMM : 13.00.00.01
PMHEXDMP : 13.00.00.01
PMUNXDSK : 13.00.00.01
ICUVER : TDICU, 13.00.00.01
CLIV2 : 13.00.00.25
MTDP : 13.00.00.15
MOSIos : 13.00.00.05
MOSIDEP : 13.00.00.02
OSENCRYPT : N/A
OSERR : 13.00.00.00
FastLoad linking date: Mar 16 2009
===================================================================
= =
= Logon/Connection =
= =
===================================================================
0007 .LOGON 127.0.0.1/TDUSER,
**** 00:51:07 Teradata Database Release: 13.00.00.12
**** 00:51:07 Teradata Database Version: 13.00.00.12
**** 00:51:07 Current CLI or RDBMS allows maximum row size: 64K
**** 00:51:07 Character set for this job: ASCII
**** 00:51:08 Number of FastLoad sessions requested = 10
**** 00:51:08 Number of FastLoad sessions connected = 2
**** 00:51:08 FDL4808 LOGON successful
0008 DROP TABLE tduser.M1;
**** 00:51:08 Command completed successfully
0009 DROP TABLE TDUSER.ERR1;
**** 00:51:08 RDBMS error 3807: Object 'TDUSER.ERR1' does not exist.
0010 DROP TABLE TDUSER.ERR2;
**** 00:51:08 RDBMS error 3807: Object 'TDUSER.ERR2' does not exist.
0011 CREATE SET TABLE tduser.M1
(
MANUFACTURER_ID INTEGER,
MANUFACTURER_NAME VARCHAR(10),
MANFACTURE_CODE VARCHAR(3)
)
UNIQUE PRIMARY INDEX ( MANUFACTURER_ID );
**** 00:51:08 Command completed successfully
0012 SET RECORD VARTEXT "|";
**** 00:51:08 Now set to read 'Variable-Length Text' records
**** 00:51:08 Delimiter character(s) is set to '|'
**** 00:51:08 Command completed successfully
0013 DEFINE
delim0 (varchar(1)),
MANUFACTURER_ID (varchar(2)),
delim1 (varchar(1)),
MANUFACTURER_NAME (varchar(10)),
delim2 (varchar(1)),
MANFACTURE_CODE (varchar(3)),
delim3 (varchar(1)),
newlinechar (varchar(1))
FILE = C:\Documents and Settings\code.txt;
**** 00:51:08 FDL4803 DEFINE statement processed
0014 SHOW;
FILE = C:\Documents and Settings\code.txt
DELIM0 OFFSET = 0 LEN = 1 VARCHAR
MANUFACTURER_ID OFFSET = 3 LEN = 2 VARCHAR
DELIM1 OFFSET = 7 LEN = 1 VARCHAR
MANUFACTURER_NAME OFFSET = 10 LEN = 10 VARCHAR
DELIM2 OFFSET = 22 LEN = 1 VARCHAR
MANFACTURE_CODE OFFSET = 25 LEN = 3 VARCHAR
DELIM3 OFFSET = 30 LEN = 1 VARCHAR
NEWLINECHAR OFFSET = 33 LEN = 1 VARCHAR
TOTAL RECORD LENGTH = 36
0015 BEGIN LOADING TDUSER.M1 ERRORFILES TDUSER.ERR1, TDUSER.ERR2;
**** 00:51:08 Number of AMPs available: 2
**** 00:51:08 BEGIN LOADING COMPLETE
0016 .CHECKPOINT 1000;
**** 00:51:08 FDL4800 Invalid FastLoad statement
0017 .INDICATORS;
**** 00:51:08 FDL4800 Invalid FastLoad statement
===================================================================
= =
= Insert Phase =
= =
===================================================================
0018 INSERT INTO TDUSER.M1 VALUES (:MANUFACTURER_ID,:MANUFACTURER_NAME,:MANFACTU
RE_CODE) ;
**** 00:51:08 Number of recs/msg: 2570
**** 00:51:08 Starting to send to RDBMS with record 1
**** 00:51:08 Field too large in vartext data record: 1, field:
MANUFACTURER_ID
===================================================================
= =
= Logoff/Disconnect =
= =
===================================================================
**** 00:51:08 Logging off all sessions
**** 00:51:11 Total processor time used = '0.296875 Seconds'
. Start : Sun Jun 16 00:51:07 2013
. End : Sun Jun 16 00:51:11 2013
. Highest return code encountered = '12'.
**** 00:51:11 FastLoad Paused
DATA file++++++++++
1|mayank|ab
22|deepak|xy
10|father|jj
also advise please when to use default option of unformatted and formatted if using normal text file in personal computer.
what is format when we use xcel to keep data for loading.
regards,
Mayank