Hi, Feinholz,
Thanks a lot, I have one more question. I am running my tpt script and get the following error.
tbuild -f job1A.tpt -v myDesktop.var
Teradata Parallel Transporter Version 13.10.00.09
Job log: /opt/teradata/client/13.10/tbuild/logs/appworx-300.out
Job id is appworx-300, running on XXXX.com
Teradata Parallel Transporter SQL DDL Operator Version 13.10.00.09
DDL_OPERATOR: private log specified: ddl_log
DDL_OPERATOR: connecting sessions
DDL_OPERATOR: sending SQL requests
DDL_OPERATOR: TPT10508: RDBMS error 3807: Object 'XXX.ET_Trans' does not exist.
DDL_OPERATOR: TPT18046: Warning: error is ignored as requested in ErrorList
DDL_OPERATOR: disconnecting sessions
DDL_OPERATOR: Total processor time used = '0.03 Second(s)'
DDL_OPERATOR: Start : Wed Nov 21 15:53:41 2012
DDL_OPERATOR: End : Wed Nov 21 15:53:42 2012
Job step Setup_Tables completed successfully
Teradata Parallel Transporter DataConnector Version 13.10.00.09
FILE_READER Instance 1 directing private log report to 'dataconnector_log-1'.
FILE_READER Instance 2 directing private log report to 'dataconnector_log-2'.
FILE_READER: TPT19008 DataConnector Producer operator Instances: 2
FILE_READER: TPT19003 ECI operator ID: FILE_READER-2474
FILE_READER: TPT19434 pmOpen failed. General failure (34): 'pmUnxDskOpen: 'open' error (Permission denied)'
FILE_READER: TPT19304 Fatal error opening file.
TPT_INFRA: TPT02192: Error: Cannot load shared library
dlopen error: libloadop.so: wrong ELF class: ELFCLASS64
TPT_INFRA: TPT02192: Error: Cannot load shared library
dlopen error: libloadop.so: wrong ELF class: ELFCLASS64
TPT_INFRA: TPT02109: Cannot open shared library libloadop.so, status = Open Error
TPT_INFRA: TPT02109: Cannot open shared library libloadop.so, status = Open Error
TPT_INFRA: TPT02240: Error: Cannot create operator object, status = Operator Error
TPT_INFRA: TPT02240: Error: Cannot create operator object, status = Operator Error
TPT_INFRA: TPT02103: Executor unable to set up its table object
TPT_INFRA: TPT02103: Executor unable to set up its table object
FILE_READER: TPT19221 Total files processed: 0.
Job step Load_Trans_Table terminated (status 12)
Job appworx terminated (status 12)
I think the issue was due to 64-bit or 32 bit component was used but not sure how to resolve it.
Any suggestions?
Regards,
Jim
↧